Edge B
Concealed grid, suspended – not demountable

Suspended fixing on steel base GK(CD)-system in two levels
Used for all Gyptone products with edge type B.
Gyptone tiles with edge type B bevelled edges are screwed to timber battens or
steel sections. Fixing to steel sections can be done either directly or via hangers.
The tiles are filled and painted after fixing and are not demountable.
Loading
The tiles normally withstand moderate point loading (<3 kg). For higher loads, or
if there is a risk of heat transfer to the connections, fixing should be done to sections behind or via a transom to a primary section. Alternatively, the load should be suspended separately.
Main channel GK 1
L: 4000 mm
Cross channel GK(CD) 1
L: 4000 mm
Connector
GK(CD) 20
Jointing plate
GK(CD) 22
Perimeter channel GK(CD)-C
L: 3000 mm
Hangers
Adjustable GK 25
Wire for hanger
GK 150-1500, L: 125-1000 mm